YS 6800
CT Contrast Injection System
Three channel design
Convenient and minimalist
Seven inch touch screen
Side position design effectively prevents splashing of medication
Alpha Assistant
Rolling pump design
Time tested in the market
| YS6800 CT Contrast Injector – Technical Specifications | ||
| Model | YS6800 | |
| Main Controller Power Supply | AC 198–242 V, Frequency 50 ±1 Hz, 980 VA | |
| Number of Channels | Three-channel | |
| * | Maximum Injection Pressure | 330psi |
| Injection Flow Rate | 0.1–10 mL/s, increment 0.1 mL/s | |
| * | Dual-flow Injection | Supports proportional mixing of contrast media and saline; mixing ratio 5%–95% |
| Injection Phases | Supports up to 12 injection phases | |
| * |
Alpha Assistant (Intelligent Assistant) |
Supported; fully automatic connection of inner and outer tubing, automatic air removal and line priming to injection-ready status; detects outer tubing connection to prevent misoperation |
| * | Overpressure Protection | User-selectable: pressure reduction followed by stop, or immediate stop upon overpressure |
| Air Detection Alarm | Supported | |
| Ultrasonic Air Sensors | 5 | |
| Automatic Left/Right Channel Switching | Supported | |
| Automatic Inner Tube Up/Down Movement | Supported | |
| Main Operation Screen | 15-inch touchscreen | |
| On-body Operation Screen | 7-inch touchscreen | |
| * | Splash-proof On-body Screen | Side-mounted design to prevent contrast or saline dripping and interfering with operation |
| Injection Program Storage/Recall | Stores up to 2,000 programmable injection protocols | |
| * | Remaining Volume Display | Real-time display of remaining contrast volume on main or on-body screen |
| * | Automatic Remaining Volume Refresh | Automatic of remaining volume when bottle is changed mid-procedure |
| Injection / Venting Method | Direct ion of contrast bottle; no syringe, no bottle opening or aspiration required; automatic air removal | |
| * | Magnetic Bottle Holder | Magnetic holder with 90° rotation for easier bottle removal; no latch operation required |
| * | Aluminum Alloy Heating Sleeve | Optional heating sleeve; easier bottle installation/removal; no need to open the sleeve |
| * | Data Transmission | Wired or wireless (optional) |
| * | KVO (Keep Vein Open) | Supported |
| Injection Delay | 0-1000s | |
| * | Inter-phase Delay | 0-1000s |
| * | Timer | Supports start-triggered timing and injection-end-triggered timing |
| Test Injection via On-body Touchscreen | Supported; independent programming | |
| * | One-touch Automatic Preparation | Intelligent one-button preparation to injection-ready status; no complex operation memorization required |
| * | Medication Change Detection | Three-channel sensing to detect bottle replacement by operator |
| Information Workstation | Not supported | |