YS 6800

CT Contrast Injection System


Three channel design 

Convenient and minimalist


Seven inch touch screen

Side position design effectively prevents splashing of medication



Alpha Assistant


Rolling pump design

Time tested in the market



YS6800 CT Contrast Injector – Technical Specifications
  Model YS6800
  Main Controller Power Supply AC 198–242 V, Frequency 50 ±1 Hz, 980 VA
  Number of Channels Three-channel
* Maximum Injection Pressure 330psi
  Injection Flow Rate 0.1–10 mL/s, increment 0.1 mL/s
* Dual-flow Injection Supports proportional mixing of contrast media and saline; mixing ratio 5%–95%
  Injection Phases Supports up to 12 injection phases
* Alpha Assistant
(Intelligent Assistant)
Supported; fully automatic connection of inner and outer tubing, automatic air removal and line priming to injection-ready status; detects outer tubing connection to prevent misoperation
* Overpressure Protection User-selectable: pressure reduction followed by stop, or immediate stop upon overpressure
  Air Detection Alarm Supported
  Ultrasonic Air Sensors 5
  Automatic Left/Right Channel Switching Supported
  Automatic Inner Tube Up/Down Movement Supported
  Main Operation Screen 15-inch touchscreen
  On-body Operation Screen 7-inch touchscreen
* Splash-proof On-body Screen Side-mounted design to prevent contrast or saline dripping and interfering with operation
  Injection Program Storage/Recall Stores up to 2,000 programmable injection protocols
* Remaining Volume Display Real-time display of remaining contrast volume on main or on-body screen
* Automatic Remaining Volume Refresh Automatic of remaining volume when bottle is changed mid-procedure
  Injection / Venting Method Direct ion of contrast bottle; no syringe, no bottle opening or aspiration required; automatic air removal
* Magnetic Bottle Holder Magnetic holder with 90° rotation for easier bottle removal; no latch operation required
* Aluminum Alloy Heating Sleeve Optional heating sleeve; easier bottle installation/removal; no need to open the sleeve
* Data Transmission Wired or wireless (optional)
* KVO (Keep Vein Open) Supported
  Injection Delay 0-1000s
* Inter-phase Delay 0-1000s
* Timer Supports start-triggered timing and injection-end-triggered timing
  Test Injection via On-body Touchscreen Supported; independent programming
* One-touch Automatic Preparation Intelligent one-button preparation to injection-ready status; no complex operation memorization required
* Medication Change Detection Three-channel sensing to detect bottle replacement by operator
  Information Workstation Not supported

Recommend